Chromic Gut Absorbable Suture is Still a Great Suture for General Surgeries


All sutures can be divided into two main groups: absorbable or non-absorbable (also called permanent). This depends on whether the body will naturally degrade and absorb the suture material over time. Absorbable suture materials also cover the original catgut. Catgut suture is a type of surgical suture that is naturally degraded by the body's own chemical substances called enzymes. This happens because of a biological process called proteolysis. This is the breakdown of proteins in the body by multiple factors such as enzymes and heat. Catgut suture was made from pig or cow intestine, not from the gut of a cat. Absorbable sutures were in the beginning made of the intestines of sheep. Today, gut sutures are made of expressly prepared beef and sheep intestine, and may not be treated (plain gut) or tanned with chromium salts to increase their persistence in the body (chromicgut). However, the topic of our interest here is the chromic gut suture which is a variant treated with chromic acid salts. Catgut has been withdrawn from most parts of the world because pure catgut causes an intense tissue reaction as it is absorbed within three to five days. This makes it largely unacceptable today. Thus, we use catgut soaked in chromic acid as an alternative since it causes a less intense reaction and has a faster rate of absorption in comparison to synthetic absorbable sutures.  

Chromic gut surgical sutures are made of a high quality raw material for great absorption and an extremely high tensile strength. Absorption of the sutures varies according to which type of body tissue it is sewn into. It is more brown rather than straw-colored, and has improved smoothness due to the dry presentation of the thread. It is otherwise similar to plain catgut. Absorption is complete by ninety days, and full tensile strength remains for at least seven days. This ultimate breakup makes it good for use in rapidly healing tissues and in inside structures that cannot be accessed again to see if the suture can be removed. The chromic gut sutures are sometimes coated, as the coating helps reduce tissue drag and the smoothness of the strands allow for efficient knots to be tied. However, the downside is that it slows down the rate of absorption by the body. 

Chromic gut suture has high knot-pull tensile strength and good knot security due to extraordinary outstanding handling characteristics. It is used for all types of surgical procedures including general closure, ophthalmic, orthopedics and gastrointestinal surgery. It is absorbed faster in patients with cancer, anemia, and malnutrition. It also absorbed at a faster rate when used in the mouth and in the vagina, due to the existence of microorganisms. They are used therefore in many of the internal tissues of the body. When the suture is not needed any more, the fact that it disappears is an advantage, as there is no foreign material left inside the body and no need for the patient to have the sutures removed.

Monday, July 9, 2012

INTEGRA™ Bilayer Wound Matrix: One of the Best Wound Care Devices on the Market

INTEGRA™ Bilayer Wound Matrix is a state of the art wound care device. Bilayermeans being comprised of two layers. Its physical properties have made it one of the best wound dressings that are available in the market.

It is made up of a matrix of cross-linked bovine tendon collagen that is porous in nature, glycosaminoglycan and a polysiloxane layer. This is essentially a silicone layer which allows some substances to pass through but prevents others from doing so. It is a matrixthat provides a raised platform for cellular invasion and development of the capillaries. It also acts as a barrier to the entry of bacteria into the wound site.
The special characteristic of the bilayer silicon membrane is that is regulating the amount of water vapor that is lost from the wound. It also provides a flexible adherent covering to the surface of the wound and toughens up the device against wear and tear. The collagen-glycosaminoglycan can break down naturally without any special scientific treatment, and can therefore decay without causing any harm as the cells of the patient reconstruct the injured site. This can take about 14 to 21 days.

The wound is healed completely when the epidermal cells shift away from the edges of the wound. This can take up to 30 days, but it results in healing that has occurred wholly from the patients' own body tissue. For larger wounds, a piece of healthy skin of the patient's epidermis can be attached to the wound area to assist the wound dressing in closing the wound. This is known as skin grafting.

There are numerous benefits of the INTEGRA™ bilayermatrix wound dressings. Some of them include the provision of instant covering of the wound, and an elevated comfort level experience when using it on a variety of sites on the structure of the body. It has proved to work very well in deep donor sites as well, and exhibits extraordinary vigor and suppleness. It had a long shelf life you so don't have to worry about the device having passed the expiry date. In addition to such advantages, it provides excellent coverage over bone, tendon, cartilage and joints that are uncovered or open to the elements.

There was a study done in which in 166 instances, INTEGRA fruitfully closed about ninety percent of the exposed internal structures that are in general closed with flaps. In another quite different study, 107 patients were chosen that had 158 acknowledged individual users. INTEGRA was successful in healing up to ninety two percent of these patients in most cases with Integra alone.  Only in rare cases were small subsidiary flaps used alongside the bilayer wound matrix. Such high statistical figures prove that Integra is a much better wound dressing in comparison to others. Some people also call this process "skin replacement therapy".
INTEGRA™ Bilayer Wound Matrix is used for handling wounds with partial and full thickness, ulcers caused by diabetes and pressure, long term ulcers and ulcers found in the channels and veins of the body. It is also used for surgical wounds and trauma wounds that include areas of skin that have been scraped, deep cuts and tears in the skin, and burns of the second degree. The wound dressing, however, is not supposed to be used repeatedly.

If you are looking to buy DISCOUNTED BMW410 BILAYER MATRIX WOUND DRESSING sterile 5ea by Integra at Great Discounts! contact SOS Medical at 1800-3675735